Building Safety Act 2022 Explained
Guide to the Building Safety Act 2022 - the comprehensive reform of building safety regulation in England following the Grenfell Tower tragedy.
Written for England. Check the position if your property is elsewhere in the UK.
12 min
Key takeaways
- The Building Safety Act 2022 is a comprehensive reform of building safety regulation
- It created the Building Safety Regulator, originally set up within the Health and Safety Executive and now a standalone regulator
- Higher-risk buildings (residential buildings at least 18 metres tall or with at least 7 storeys) face the most stringent requirements
- Building owners must register higher-risk buildings and apply for building assessment certificates
- Leaseholders are protected from many remediation costs under the Act
What is the Building Safety Act?
The Building Safety Act 2022 is the most significant reform of building safety regulation in decades. It received Royal Assent in April 2022 and has been implemented in phases since then. The Act responds to Dame Judith Hackitt's Independent Review of Building Regulations and Fire Safety following the Grenfell Tower tragedy.
Do not use these terms interchangeably
"Responsible person" under the Fire Safety Order, "Accountable Person/Principal Accountable Person" under the Building Safety Act and Building Regulations dutyholders are distinct legal concepts, although the same organisation can sometimes hold more than one role. The Building Safety Act's higher-risk-building in-occupation regime and the Fire Safety Order's Section 156 recording/co-operation changes both took effect around 1 October 2023, but they are separate legal frameworks with separate dutyholders: one is not simply part of the other.
Key Elements of the Act
- Building Safety Regulator: Originally set up within the HSE and now a standalone regulator, with responsibilities for building safety and building control.
- Higher-risk buildings regime: New regulatory requirements for residential buildings at least 18m in height or with at least 7 storeys.
- Accountable persons: New duty holders responsible for managing building safety in occupied higher-risk buildings.
- Golden thread of information: Requirement to create and maintain key building safety information throughout a building's life.
- Leaseholder protections: Limits on what leaseholders can be charged for historical building safety defects.
Higher-Risk Buildings
The Building Safety Act creates a new regulatory regime for "higher-risk buildings" - those that are at least 18 metres tall or have at least 7 storeys and contain at least two residential units.
Requirements for Higher-Risk Buildings
- Registration: All higher-risk buildings must be registered with the Building Safety Regulator.
- Building assessment certificate: Accountable persons must apply for a certificate demonstrating compliance.
- Safety case report: Document demonstrating how building safety risks are managed.
- Mandatory occurrence reporting: Duty to report certain fire and structural safety occurrences.
- Residents' engagement: Strategy for engaging residents on building safety matters.
Accountable Persons
The Act introduces the concept of "accountable persons" - individuals or organisations responsible for building safety in occupied higher-risk buildings. The principal accountable person has overall responsibility.
Accountable Person Duties
- Assess building safety risks: Assess risks to the safety of people in and around the building from fire spread and structural failure.
- Manage those risks: Take reasonable steps to prevent risks materialising and reduce severity if they do.
- Prepare safety case report: Document the assessment and management of building safety risks.
- Register and apply for certificate: Register the building and apply for a building assessment certificate.
- Cooperate with others: Work with other accountable persons, the regulator, and residents.
Additional responsible-person duties in force from 1 October 2023
Section 156 of the Building Safety Act 2022 changed the Fire Safety Order regime in England from 1 October 2023.
A responsible person must now record the fire risk assessment in full and record the fire-safety arrangements, irrespective of the number of employees. Where another person or organisation is engaged to undertake or review the fire risk assessment, record that person's identity or, as applicable, the organisation's identity.
The responsible person must also keep the required responsible-person information current and comply with applicable information-sharing and co-operation duties. This includes taking reasonably practicable steps to identify other responsible persons who share or have duties in respect of the premises and, where relevant, Accountable Persons under the Building Safety Act regime; the relevant parties must exchange the required information and co-operate.
Where responsibility for premises changes, the outgoing responsible person must provide the incoming responsible person with relevant fire-safety information required by the legislation. For buildings containing two or more sets of domestic premises, responsible persons also have additional duties to provide relevant fire-safety information to residents in an understandable form.
These changes were not limited to holiday lets or high-rise residential buildings.
Leaseholder Protections
The Building Safety Act includes significant protections for leaseholders from the costs of remediating historical building safety defects, particularly cladding and other fire safety issues.
Leaseholder Cost Protections
Qualifying leaseholders (those meeting certain criteria) cannot be charged for the remediation of relevant defects like unsafe cladding. Landlords who meet responsibility conditions must pay. Complex rules apply - seek legal advice for specific situations.
Implementation Timeline
- April 2022: Act received Royal Assent.
- April 2023: Higher-risk building registration opened.
- October 2023: New in-occupation regime for higher-risk buildings came into force.
- Ongoing: Building assessment certificate applications now being processed.
Frequently Asked Questions
+Is my building a higher-risk building?
If your building is at least 18 metres tall (or has at least 7 storeys) and contains at least 2 residential units, it is likely a higher-risk building under the Act. The Building Safety Regulator can help confirm.+Who is the accountable person for my building?
The accountable person is typically whoever owns or has responsibility for the common parts. For a single freehold owner, they are the principal accountable person. For buildings with multiple owners or management structures, there may be multiple accountable persons.+What if my building is under 18m and fewer than 7 storeys?
A building that is under 18 metres and has fewer than 7 storeys is not a higher-risk building for Building Safety Act purposes. It remains subject to the Fire Safety Order and the Fire Safety Act 2021, and the Fire Safety (England) Regulations 2022 (resident information duties for any building with two or more flats, plus fire-door checks if more than 11 metres high). A building more than 11 metres high using a simultaneous evacuation strategy may also fall within the separate Fire Safety (Residential Evacuation Plans) (England) Regulations 2025.
Next Steps
If you manage a higher-risk building, ensure you understand your accountable person duties.
Sources
- Building Safety Act 2022 — UK Parliament, accessed 2026-09-16
- Building Safety Regulator — GOV.UK, accessed 2026-09-16
Need a fire risk assessment?
Tell us about the building and what you need, and we’ll let you know how we can help.