Fire Doors & Escape Routes for Holiday Lets

Essential guidance on fire doors, escape routes, and emergency lighting for holiday let properties. Keep your guests safe with proper means of escape.

Written for England. Check the position if your property is elsewhere in the UK.

9 min

Key takeaways

  • Every bedroom must have access to a clear escape route that doesn't pass through a high-risk room
  • Fire-resisting doors and escape routes must be proportionate to the premises and assessed risk - not every existing door needs replacing with a newly certified doorset
  • Final exit doors must be openable from inside without a key when the property is occupied
  • Alternative escape routes should be identified for upper floors if the main route could be blocked
  • Emergency lighting and signage are risk-based, not a fixed universal requirement for every simple holiday let

Why Escape Routes Matter

In a fire, the ability to escape quickly and safely is critical. For holiday lets, this is especially important because guests are unfamiliar with the property layout and may be disoriented if woken at night. Your fire risk assessment must evaluate whether your escape routes are adequate and clearly communicated to guests.

Key Principles

  • Ideally two ways out: From each sleeping area, there should be a primary escape route and an alternative if the first is blocked.
  • Avoid passing through high-risk areas: Escape routes should not pass through kitchens or other rooms where fires are most likely to start.
  • Clear and unobstructed: Routes must be free from obstructions at all times. No locked doors, stored items, or blocked corridors.
  • Known to guests: Guests must be informed of escape routes on arrival, typically through signage and welcome information.

Single Staircase Properties

Most holiday cottages have a single staircase. If fire blocks this staircase, guests on upper floors need an alternative escape. This could be an escape window, roof access, or other means identified in your fire risk assessment.

Assessing Your Escape Routes

Walk through your property and assess each bedroom's escape options:

  1. Identify the primary route: The main way from each bedroom to the final exit. Usually through hallways and down stairs.
  2. Check for obstructions: Are corridors wide enough? Any permanently stored items blocking the route?
  3. Consider high-risk areas: Does the route pass through or close to the kitchen? Near electrical equipment?
  4. Evaluate the final exit: Can the door be opened quickly from inside without a key?
  5. Identify alternatives: What if the primary route is blocked? Is there a secondary staircase, escape window, or other option?

Fire-Resisting Doors

Fire-resisting doors and escape routes must be proportionate to the premises and assessed risk. Do not assume that every existing small guest property requires wholesale replacement of all doors with newly certified doorsets. The current Home Office small-premises guidance includes circumstances in which existing substantial or notional fire-resisting doors may form part of an acceptable solution. Whether a door needs a particular fire resistance, smoke control, self-closing device, seals or replacement depends on its location, the escape strategy, the building and applicable guidance.

Do not apply the simplified approach outside its scope

Open-plan layouts, inner-room arrangements or other materially different configurations can require a different solution and should be assessed against the appropriate sleeping-accommodation guidance, with competent advice where needed.

Locations Where a Fire-Resisting Door May Be Needed

  • Kitchen doors: Where the kitchen opens onto an escape route, a door separating the kitchen from the hallway or staircase is a common risk-control measure - confirm through the FRA.
  • Bedroom doors: In some properties, particularly larger ones or those with inner rooms, bedroom doors may need to be fire-resisting.
  • Living room doors: Where the living room contains significant fire risks and opens onto an escape route.
  • Utility rooms/boiler rooms: Rooms containing boilers or significant electrical equipment.

Fire Door Ratings

These ratings describe the performance of a certified doorset where a new fire door is being specified. They are not a rule that every existing door in every holiday let must be replaced to this standard - see the note above.
RatingProtection TimeTypical Use
FD3030 minutesThe most common rating specified for new fire doors in domestic-scale situations, where the FRA identifies that a fire door is needed
FD6060 minutesHigher-risk situations. Rarely required for small holiday lets.

What to Establish for an Existing or New Fire Door

Establish first what performance the particular door is intended to provide and what evidence exists for the doorset or existing construction. Dimensions, hardware and seal requirements set out below are technical inspection considerations, not a universal statutory checklist for every historical or proprietary doorset.

  • Door leaf: A certified fire door cannot be created from a standard door leaf using surface treatments alone.
  • Door frame: Should be designed to work with the door. Gaps around the door are a technical indicator to check, not a freestanding legal test - excessive or inconsistent gaps warrant further investigation.
  • Intumescent strips: Where required, these expand in heat to seal gaps between door and frame, usually combined with smoke seals.
  • Self-closing device: Where a self-closing device is required, verify that it closes the door reliably into its frame from realistic opening positions.
  • Hinges: Where fire-rated hinges are required, check they are secure and appropriate to the doorset - the number and type is a certification detail, not a universal legal minimum for every door.
  • Handles and latches: Should be compatible with the door's required performance. Avoid letterboxes or cat flaps in fire-resisting doors.

What to Inspect

Inspect for damage, distortion, excessive or inconsistent gaps, condition of the leaf and frame, glazing, hinges and other ironmongery, any required seals, the latching/closing function where required, and any unauthorised alteration or penetration. Compare the door with the building's fire strategy, available certification or manufacturer evidence, applicable current technical guidance and the FRA. Where the required performance cannot be established or defects may compromise it, obtain competent fire-door advice.

Regularly check the condition of doors identified as fire-resisting in your FRA:

  1. Does the door close fully into the frame?: Without catching or requiring a push, where a self-closer is fitted.
  2. Are intumescent strips intact?: Check for damage, paint coverage, or missing sections.
  3. Is the self-closer working?: The door should close automatically from any angle, where fitted.
  4. Are there gaps around the door?: Note the gaps and compare with the doorset's certification evidence or manufacturer's guidance where available.
  5. Any damage or holes?: Even small holes can compromise fire resistance. Check for damage from locks, viewers, or alterations.
  6. Are hinges secure?: All screws tight, no missing fixings.

Don't Prop Fire Doors Open

Fire doors only work when closed. Never wedge fire doors open with door stops or furniture. If a door needs to be held open routinely, a magnetic hold-open device linked to the fire alarm can be installed.

Final Exit Doors

The final exit door is the door guests use to leave the building in an emergency. This is usually the main entrance door but could also be a back door or other exit.

Final Exit Requirements

  • Openable from inside without a key: When guests are present, they must be able to open the door from inside without a key. Fit a thumb-turn or similar inside release.
  • Adequate width: Wide enough for people to exit quickly. Standard door width is usually sufficient for small properties.
  • Clear outside: The area outside the door should be clear. No bins, furniture, or plants blocking the exit.
  • Easily identified: Guests should know which door is the main escape route. Mark with signage if not obvious.

No key needed to get out

If your final exit door can only be opened from inside with a key, change the lock to one with a thumb-turn or similar inside release. A key left on a hook or in the lock can be moved, lost or hard to find in smoke, so it is not a safe substitute.

Escape Windows

In properties where the only staircase could be blocked by fire, upper-floor bedrooms may need an alternative escape route via a window.

Escape Window Requirements

  • Minimum opening size: At least 450mm high and 450mm wide with an opening area of at least 0.33m².
  • Sill height: Bottom of opening should be no more than 1100mm above floor level.
  • Accessible escape: Must lead to an area where rescue is possible. Ground level or a flat roof with access to ground.
  • Easily openable: Should open without special tools or keys. Guests should be able to operate in an emergency.

Emergency Lighting and Signs Are Risk-Based

Do not treat conventional emergency escape lighting and exit signage as a universal requirement for every simple holiday let. The official small-premises guide allows proportionate solutions in appropriate simple layouts. Record in your FRA why the measures you have chosen provide adequate escape under loss-of-light conditions.

Where Emergency Lighting Is More Likely to Be Needed

  • Windowless areas on escape routes: Internal corridors or stairways with no natural light.
  • Complex layouts: Properties where guests could become disoriented in darkness.
  • Larger properties: Properties with multiple bedrooms and longer escape routes.
  • Basement rooms: Any basement or lower ground floor sleeping accommodation.

Emergency Lighting Options

  • Maintained emergency lights: Always on, with battery backup. Common in commercial settings.
  • Non-maintained emergency lights: Only activate when mains power fails. More common in domestic settings.
  • Torches as an alternative: For simpler properties, battery torches in known locations may be acceptable. Must be maintained and guests informed.

Fire Safety Signage

Clear signage helps guests identify escape routes and fire safety equipment, especially important as they are unfamiliar with the property.

Types of Signage

  • Fire exit signs: Where signs are needed, green escape signs showing the running-person symbol with an arrow pointing the way out (with "Fire exit" wording where it helps), at exits and along escape routes. Words alone are not enough.
  • Fire action notices: What to do in case of fire. Should include escape route, assembly point, and emergency number.
  • Fire door signs: "Fire door keep shut" signs on fire doors.
  • Equipment location signs: Signs indicating location of fire extinguishers, blankets, and alarm call points.

Proportionate Signage

Small holiday cottages don't need the same signage as commercial premises. At minimum, provide a fire action notice and mark the final exit if not obvious. Your fire risk assessment will identify any additional signage needed.

Communicating with Guests

Your guests need to know how to escape in an emergency. Include the following in your welcome information:

  • Escape route from each bedroom: Describe or show on a plan how to exit from sleeping areas.
  • Final exit door location: Which door to use and how to open it from inside.
  • Assembly point: Where to gather outside once evacuated (away from the building).
  • Emergency number: Remind guests to call 999 for fire. Include your contact number for non-emergencies.
  • Torch locations: If you provide torches, tell guests where to find them.

Frequently Asked Questions

  • +My property has old doors. Do I need to replace them all with fire doors?
    Not necessarily. Your fire risk assessment will determine where fire doors are needed based on your specific property. Focus on doors that separate escape routes from high-risk areas (typically kitchens). Upgrading specific doors may be more practical than replacing all doors.
  • +My cottage only has one exit. Is that acceptable?
    Many small holiday properties only have one main exit, and this can be acceptable if other safety measures are in place. Your fire risk assessment should consider early detection (interlinked smoke alarms), fire containment (fire doors), and alternative escape from upper floors (escape windows).
  • +How do I balance security with escape requirements?
    Use a thumb-turn lock on the inside of the final exit door so guests can always open it without a key. You can still have a keyed lock on the outside for security. Do not rely on a key left on a hook or in the lock instead.
  • +How do I know if my doors are certified fire doors?
    A newly installed fire door should have a certification label (often on the top edge) showing the fire rating (e.g., FD30). An older or notional fire-resisting door may not carry a label yet still form part of an acceptable solution in the circumstances described by the Home Office small-premises guide - establish what evidence exists and what performance the door needs to provide, and seek competent advice if you are unsure.

Meeting a recommendation is not automatically compliance

Meeting an individual recommendation does not by itself establish compliance with the Fire Safety Order. Measures must be appropriate to the premises, persons at risk and findings of the suitable and sufficient fire risk assessment.

Next Steps

Document your escape routes and fire doors in your fire risk assessment. Our DIY assessment asks guided questions about your property and finishes with your own fire safety checklist.

Start the free DIY checkBook an in-person assessment