How Approved Document B and the Building Regulations relate to fire safety in building work, and how this differs from the Fire Safety Order's ongoing occupation-management duties.

Written for England. Check the position if your property is elsewhere in the UK.

8 min

Key takeaways

  • Approved Document B provides guidance on satisfying the Building Regulations for building work - it is a separate regime from the Fire Safety Order's ongoing occupation-management duties
  • Amendments that took effect on 2 March 2025 affect new care homes (including sprinkler provision), fire-classification references and Regulation 38-related material
  • Further amendments that took effect on 30 September 2026 require a second common stair in relevant new blocks of flats with a storey at least 18 metres high and add design provisions supporting evacuation lifts, subject to transitional provisions for work already applied for
  • An existing building that does not match the current new-build Approved Document recommendation is not automatically unlawful under the Fire Safety Order for that reason alone
  • Historic Building Regulations approval does not relieve a responsible person of current Fire Safety Order duties

Building Regulations, Approved Document B and the Fire Safety Order

Building Regulations fire-safety requirements and duties under the Regulatory Reform (Fire Safety) Order 2005 are related but legally distinct. Approved Document B provides guidance on satisfying applicable Building Regulations requirements for building work; it should not be used as a substitute for the ongoing premises-management duties of the responsible person under the Fire Safety Order.

Two different regimes

Approved Document B concerns compliance with the Building Regulations in connection with building work and design at the point of construction or alteration. The Fire Safety Order concerns the ongoing management of fire safety in an occupied building. Meeting Approved Document B for new work does not, by itself, discharge the responsible person's Fire Safety Order duties, and a building that met the Building Regulations when built is not automatically compliant with the Fire Safety Order today.

Current 2025 Amendments

Amendments that took effect on 2 March 2025, subject to the published transitional provisions, include changes affecting new care homes, including sprinkler provision, together with amendments to fire-classification references and Regulation 38-related material. Check the applicable edition and transitional arrangements for each project rather than assuming the latest text automatically applies to work already within an earlier transition.

Changes from 30 September 2026

Further Approved Document B amendments took effect on 30 September 2026. They include provisions requiring more than one common stair in relevant new blocks of flats with a storey at least 18 metres in height, together with design provisions supporting evacuation lifts. Under the transitional provisions, the earlier guidance can still apply where an application was made before 30 September 2026 and the work had started and was sufficiently progressed before that date, or starts and is sufficiently progressed before 30 March 2028. New applications must follow the amended guidance.

Existing Buildings

Do not infer solely from an existing building's failure to match a current new-build Approved Document recommendation that the building is automatically unlawful under the Fire Safety Order. Equally, historic Building Regulations approval does not relieve the responsible person of current Fire Safety Order duties. Assess the occupied building and risks under the legislation that currently applies.

Frequently Asked Questions

  • +What is Approved Document B?
    Approved Document B is official guidance on ways to satisfy the fire-safety requirements of the Building Regulations for building work in England. It is a design and construction document, not a substitute for the ongoing Fire Safety Order duties of the responsible person once a building is occupied.
  • +Does Approved Document B apply to my existing building?
    Approved Document B applies to building work - new build, extension, renovation or material change of use - assessed against the edition and transitional provisions in force at the relevant time. It does not retrospectively require every existing building to be rebuilt to the current edition's new-build standard, but the responsible person must still manage fire risk in the occupied building under the Fire Safety Order.
  • +What changed on 30 September 2026?
    Further Approved Document B amendments took effect, concerning a second common stair for relevant new blocks of flats with a storey at least 18 metres high, and evacuation-lift design provisions. Work applied for before that date may still follow the earlier guidance if it is sufficiently progressed before 30 March 2028, so check the transitional rules for any project already underway.

Next Steps

For occupied premises, make sure your fire risk assessment reflects current conditions rather than relying solely on historic Building Regulations approval.