Fire Door Inspection Requirements for Landlords

Guide to fire door requirements and inspection standards for rental properties. Understand when fire doors are needed and how to maintain them.

Written for England. Check the position if your property is elsewhere in the UK.

8 min

Key takeaways

  • Fire doors are typically required in HMOs on bedrooms, kitchens, and doors to escape routes
  • Required fire-door performance depends on the door's location, the escape strategy and the fire risk assessment - it is not a single fixed specification for every door
  • Fire doors only perform as designed when the leaf, frame, seals, hinges and, where required, self-closing device all work together
  • For buildings more than 11 metres high, Regulation 10 of the Fire Safety (England) Regulations 2022 sets statutory check frequencies: communal fire doors at least every 3 months, and flat entrance doors using best endeavours at least every 12 months
  • Damaged or defective fire doors need prompt, risk-based action, from interim controls through to repair or replacement

Purpose of Fire Doors

Fire doors are designed to resist fire and smoke for a specified period, commonly 30 minutes, though the performance actually required depends on the door's location and the building's fire strategy. Their purpose is to compartmentalize fire, slowing its spread and protecting escape routes so occupants have time to evacuate safely. A fire door is only as effective as its weakest component - the door, frame, seals, and closer all contribute to its fire resistance.

When Fire Doors Are Required

  • HMO bedroom doors: All bedroom doors in HMOs should be fire doors where they open onto escape routes.
  • Kitchen doors: Where kitchens open onto escape routes (hallways, stairs).
  • Communal area doors: Doors separating communal areas from escape routes.
  • Staircase enclosures: Doors that form part of a protected staircase.

Single-Let Properties

Single-let properties (rented to one household) do not typically require fire doors. However, if your fire risk assessment identifies a need for enhanced fire protection, fire doors may be recommended.

What to Inspect

Establish first what performance the particular door is intended to provide and what evidence exists for the doorset or existing construction. Inspect for damage, distortion, excessive or inconsistent gaps, condition of the leaf and frame, glazing, hinges and other ironmongery, any required seals, the latching/closing function where required, and any unauthorised alteration or penetration. Where a self-closing device is required, verify that it closes the door reliably into its frame from realistic opening positions.

Dimensions, hardware and seal requirements are not universal across every historical or proprietary doorset. Compare the door with the building's fire strategy, available certification/manufacturer evidence, applicable current technical guidance and the FRA. Where the required performance cannot be established or defects may compromise it, obtain competent fire-door advice.

For buildings to which Regulation 10 of the Fire Safety (England) Regulations 2022 applies, follow the statutory frequency: checks of communal fire doors at least every three months and best endeavours to check every flat entrance door at least every 12 months.

A defective flat entrance door

Assess the seriousness immediately, implement proportionate interim risk controls where necessary, and arrange competent repair or replacement with urgency appropriate to the risk. A flat entrance door cannot ordinarily be treated like an item of equipment that is simply 'taken out of service' while the dwelling remains occupied.

Common Problems to Look For

  • Doors propped open: Remove wedges or door stops. If doors need to be held open, install magnetic hold-open devices linked to the fire alarm.
  • Broken self-closers: Repair or replace immediately where a self-closing device is required. A door that no longer closes automatically is not providing its intended protection.
  • Inconsistent or excessive gaps: Gaps too large allow smoke through; gaps too small prevent door closing. Compare against the doorset's evidence and adjust or replace as needed.
  • Holes or damage: Any penetration through the door (for cables, letterboxes) can compromise fire resistance and should be assessed.
  • Over-painting: Thick paint buildup can prevent proper closure or obscure seals and should be assessed rather than assumed to automatically fail the door.

Meeting a recommendation is not automatically compliance

Meeting an individual recommendation does not by itself establish compliance with the Fire Safety Order. Measures must be appropriate to the premises, persons at risk and findings of the suitable and sufficient fire risk assessment.

Frequently Asked Questions

  • +Can I upgrade standard doors to fire doors?
    Converting a standard internal door into a certified fire door is not simply a case of adding strips or a closer - the performance depends on evidence for the specific leaf, frame and hardware as a tested or notional assembly. Where a fire door is required, use a doorset with appropriate certification or evidence, or obtain competent fire-door advice on whether an existing door can be shown to provide adequate performance.
  • +Can fire doors have glass panels?
    Yes, but only with fire-rated glazing that matches the door's fire rating. Standard glass is not fire-resistant. Any glazing must be properly fitted with appropriate beading.
  • +How do I know if a door is a fire door?
    Fire doors should have a certification label (often on the top edge) showing the fire rating. They're typically heavier than standard doors. If there's no label and you're unsure, assume it's not a fire door and seek competent advice.

Next Steps

Document your fire door inspections as part of your fire risk assessment records.