HMO Fire Safety Requirements

Complete guide to fire safety requirements for Houses in Multiple Occupation (HMOs). Understand fire alarm systems, fire doors, escape routes, and landlord obligations.

Written for England. Check the position if your property is elsewhere in the UK.

12 min

Key takeaways

  • HMOs have stricter fire safety requirements than single-let properties due to the increased risk
  • Mandatory HMO licensing no longer depends on the property having 3 or more storeys - the storey condition was removed in England in 2018
  • Fire alarm requirements should be determined by the property category, occupancy and fire risk assessment, not selected solely from the number of storeys
  • Fire doors are typically required on bedrooms and kitchens opening onto escape routes in HMOs, but the required performance depends on context
  • A fire risk assessment of the common parts must be carried out and recorded in full, including the fire-safety arrangements and the identity of anyone engaged to complete or review it
  • Emergency lighting and fire escape routes must be maintained and clearly marked

What is an HMO?

A House in Multiple Occupation (HMO) is a property rented by 3 or more tenants who form more than one household and share facilities such as kitchens, bathrooms, or toilets. HMOs present a higher fire risk than single-let properties because multiple people, often strangers to each other, live in close proximity and share common areas.

Types of HMO

  • Bedsit-style HMOs: Individual rooms with shared kitchen and bathroom facilities.
  • Shared houses: Properties where tenants have their own bedrooms but share living spaces.
  • Buildings converted to flats or bedsits: Converted properties that may lack purpose-built fire separation.
  • Large HMOs: An HMO occupied by 5 or more people forming 2 or more households may fall within mandatory licensing, subject to the statutory definitions and exemptions - see the licensing section below.

Mandatory and additional HMO licensing

The old requirement that an HMO also be three or more storeys high for mandatory licensing was removed in England in 2018. The mandatory regime broadly captures qualifying HMOs occupied by five or more people forming two or more households, subject to the detailed statutory definitions and exemptions. A local authority may also operate an additional HMO licensing scheme covering properties outside the national mandatory category. Check the relevant local authority before assuming a property is unlicensed merely because it is small or has fewer than three storeys.

Fire precautions in an HMO can arise from more than one legal regime. Do not use the presence or absence of an HMO licence as the sole test of Fire Safety Order obligations. Consider the Housing Act/HMO management and licensing regime alongside the Fire Safety Order where applicable, and apply the current fire-risk assessment to the premises and occupancy.

Fire Risk Assessment Requirements

Under the Regulatory Reform (Fire Safety) Order 2005, you must carry out a fire risk assessment of the common parts of your HMO. This includes hallways, stairs, landings, shared kitchens, and any other communal areas. The assessment must be recorded in full and kept up to date - see the additional responsible-person duties below.

Legal Requirement

As the landlord of an HMO, you will usually be the "responsible person" under fire safety law for the common parts, though responsibility can also depend on control and management arrangements. Failure to have an adequate fire risk assessment can result in prosecution, fines, and imprisonment.

Additional responsible-person duties in force from 1 October 2023

Section 156 of the Building Safety Act 2022 changed the Fire Safety Order regime in England from 1 October 2023.

A responsible person must now record the fire risk assessment in full and record the fire-safety arrangements, irrespective of the number of employees. Where another person or organisation is engaged to undertake or review the fire risk assessment, record that person's identity or, as applicable, the organisation's identity.

The responsible person must also keep the required responsible-person information current and comply with applicable information-sharing and co-operation duties. This includes taking reasonably practicable steps to identify other responsible persons who share or have duties in respect of the premises and, where relevant, Accountable Persons under the Building Safety Act regime; the relevant parties must exchange the required information and co-operate.

Where responsibility for premises changes, the outgoing responsible person must provide the incoming responsible person with relevant fire-safety information required by the legislation. For buildings containing two or more sets of domestic premises, responsible persons also have additional duties to provide relevant fire-safety information to residents in an understandable form.

These changes were not limited to holiday lets or high-rise residential buildings.

Fire Alarm System Requirements

The type of fire alarm system required depends on the size and layout of your HMO. The LACoRS guidance provides indicative recommendations based on building height and configuration, but the appropriate system must be confirmed against the actual property and its fire risk assessment.

Indicative Fire Alarm System Grades (LACoRS Examples)

Illustrative examples drawn from LACoRS guidance, not a statutory table. Actual requirements must be established from the property category, layout, occupancy and current risk assessment.
HMO TypeIndicative SystemDescription
2-storey HMOGrade D LD3Mains-powered interlinked smoke alarms on each floor and in escape routes
3-storey HMOGrade A LD2Full fire alarm system with detectors in escape routes, kitchens (heat), and living rooms
4+ storey HMOGrade A LD2As above, may require additional measures based on risk assessment

Do not select an alarm category from storey count alone

The specification must be established from the property category, layout, occupancy characteristics, escape arrangements, local licensing requirements, current risk assessment and applicable technical guidance. The examples in LACORS are guidance, not a statutory one-size-fits-all specification.

Technical standards referenced by IgniRisk

IgniRisk cites British Standards and PAS documents as recognised technical references where relevant. Unless a particular statutory, approval, licensing or contractual provision makes a requirement binding, a British Standard is not itself primary legislation.

Standards are revised from time to time, so check you are using the current edition. Relevant references include PAS 79-1:2020 for non-housing fire risk assessment, BS 9999:2017, BS 5839-1:2025 for non-domestic fire detection and alarm systems and BS 5839-6:2019+A1:2020 for domestic-premises fire detection and alarm systems. Use the standard appropriate to the actual premises and purpose; do not copy requirements from one standard into a different building type without justification.

Understanding Fire Alarm Categories

  • LD3 (Life Protection - Basic): Detection in escape routes only. Not a default minimum for HMOs: the grade and coverage an HMO needs depend on its size, layout and how it is let, and the fire risk assessment sets them.
  • LD2 (Life Protection - Enhanced): Detection in escape routes plus high-risk rooms (kitchens, living rooms). Often specified for larger or multi-storey HMOs, subject to the FRA.
  • LD1 (Life Protection - Full): Detection in escape routes and in every room or space where a fire could start; spaces with very little fire risk, such as bathrooms and toilets, can be left out. Highest level of protection.

Fire Door Requirements

Fire doors are critical in HMOs to contain fire and smoke, protecting escape routes and giving occupants time to evacuate. Where a fire door is required and to what standard depends on the property's layout, escape strategy and fire risk assessment - see our dedicated fire door guide for inspection considerations.

Where Fire Doors Are Typically Required

  • Bedroom doors: Bedroom doors opening onto an escape route are commonly required to be fire-resisting; confirm the required performance and self-closing arrangement from the FRA.
  • Kitchen doors: Kitchen doors opening onto escape routes are commonly required to be fire-resisting doors; confirm the required performance from the FRA.
  • Living room doors: Where living rooms open onto escape routes, fire-resisting doors are typically required.
  • Doors to protected staircases: Doors separating the staircase from corridors must be fire-resisting as part of the protected escape route.

Fire Door Performance

  • Required fire resistance: The fire resistance a door must provide depends on its location within the escape strategy, the building and the fire risk assessment - there is no single figure that applies to every internal door. See our fire door inspection guide
  • Self-closing devices: Where a self-closing device is required, it must close the door reliably into its frame from realistic opening positions; not every internal door requires one.
  • Seals: Where required by the door's specification, intumescent strips and smoke seals must be fitted and in good condition.
  • Gaps and general condition: Check for damage, distortion and excessive or inconsistent gaps around the leaf and frame. Specific gap tolerances depend on the doorset's certification or evidenced construction, not a single universal figure for every historical door.

Escape Routes

HMO occupants must be able to escape safely from any room in the building. Escape routes must be protected from fire and smoke, clearly identified, and kept clear at all times.

Escape Route Requirements

  • Protected route: The escape route (usually the staircase and hallways) must be enclosed by fire-resisting construction.
  • Keep clear: Escape routes must be free from obstructions. No storage in hallways or on stairs.
  • Final exit: The main exit door must be openable from inside without a key at all times.
  • Fire exit signage: Clear signage indicating the escape route and final exit location.

Emergency Lighting

Whether emergency lighting is needed, and where, must be determined from the premises and the fire risk assessment rather than treated as a fixed rule for every HMO of a given size.

Factors That Increase the Likelihood Emergency Lighting Is Needed

  • Multi-storey HMOs: HMOs of 3 or more storeys often need emergency lighting on escape routes; confirm through the FRA.
  • Basement accommodation: Properties with basement bedrooms often need emergency lighting; confirm through the FRA.
  • Windowless escape routes: Any escape route without natural light is likely to need emergency lighting; confirm through the FRA.

Ongoing Management

Fire safety in HMOs is not a one-time task. Regular testing, maintenance, and management are essential to ensure continued compliance.

Regular Fire Safety Tasks

  • Test fire alarms weekly: Activate the test function and ensure all alarms sound correctly.
  • Test emergency lighting monthly: Check that emergency lights function and illuminate escape routes.
  • Check fire doors monthly: Ensure doors close properly, seals are intact, and closers work.
  • Inspect escape routes weekly: Check routes are clear of obstructions and exit doors open freely.
  • Review your fire risk assessment: Review regularly and whenever there is reason to suspect the assessment is no longer valid or a significant change has occurred - see the review guidance below.

Reviewing your fire risk assessment

Review the fire risk assessment regularly so that it remains up to date, and review it promptly where there is reason to suspect it is no longer valid or where a significant change has occurred. A sector-specific guide may recommend a routine interval; that does not replace the statutory review triggers.

Meeting a recommendation is not automatically compliance

Meeting an individual recommendation does not by itself establish compliance with the Fire Safety Order. Measures must be appropriate to the premises, persons at risk and findings of the suitable and sufficient fire risk assessment.

Frequently Asked Questions

  • +Does my HMO need a licence?
    Mandatory licensing broadly applies to HMOs occupied by 5 or more people forming 2 or more households, subject to the statutory definitions and exemptions. The old condition requiring 3 or more storeys was removed in England in 2018. Many councils also have additional licensing schemes covering smaller HMOs. Check with your local authority.
  • +Can tenants have locks on their bedroom doors?
    Yes, tenants can have locks on their bedroom doors, and these should not interfere with the operation of fire doors. However, landlords should have a master key for emergencies and be able to access rooms for fire safety checks.
  • +What fire safety responsibilities do tenants have?
    Tenants must not interfere with fire safety equipment, keep their rooms reasonably clear of fire hazards, report any defects to fire safety equipment, and follow the fire safety instructions provided by the landlord.

Next Steps

Need a fire risk assessment for your HMO? Book an in-person assessment with one of our assessors.

Book an in-person assessment