LACoRS Housing Fire Safety Guidance Explained
Jargon-free guide to the LACoRS (Local Authorities Coordinators of Regulatory Services) housing fire safety guidance for HMO landlords.
Written for England. Check the position if your property is elsewhere in the UK.
10 min
Key takeaways
- LACoRS guidance is a legacy sector reference long used by local authorities when assessing HMO fire safety, but it is not itself current primary legislation
- The guidance uses a risk-based approach that considers building height, layout, and conversion history
- Fire protection requirements increase with building height and complexity
- Following LACoRS does not by itself establish compliance - current legislation and standards take precedence where they differ
- The guidance provides indicative specifications for fire alarms, doors, and escape routes that should be checked against the current fire risk assessment
Status of LACoRS guidance
The LACORS housing fire-safety guidance is an important sector reference but is not itself current primary legislation and predates major changes including the Fire Safety Act 2021, the Fire Safety (England) Regulations 2022, the October 2023 Fire Safety Order amendments and the Fire Safety (Residential Evacuation Plans) (England) Regulations 2025. Use LACORS as part of the evidence base, not as a guarantee of present-day legal compliance. Where a later statute, statutory instrument, official guidance or current applicable standard differs, use the current requirement.
What is LACoRS Guidance?
The LACoRS (Local Authorities Coordinators of Regulatory Services) Housing Fire Safety Guidance is a document published in 2008 to provide a consistent approach to fire safety in residential properties, particularly HMOs. Many local authority environmental health and housing officers have historically used it as a reference point when assessing fire safety compliance in HMOs, but it predates several major legislative changes - see the status note above.
Why is LACoRS Guidance Still Useful?
- Historical benchmark: LACoRS was long treated as a benchmark used by local authorities across England and Wales, though it should now be read alongside current legislation and standards.
- Consistent approach: Provides a broadly uniform starting point regardless of which local authority area your HMO is in.
- Part of the evidence base: LACoRS can inform your fire risk assessment, but following it alone does not by itself establish compliance with current fire-safety legislation - see the status note above.
- Licensing conditions: Many HMO licences include conditions based on LACoRS recommendations.
The Risk-Based Approach
LACoRS guidance uses a risk-based approach that considers several factors to determine the appropriate level of fire protection. The higher the risk, the more protection required.
Risk Factors Considered
- Building height: Taller buildings require more protection as escape becomes more difficult.
- Layout and complexity: More complex layouts with longer escape routes need enhanced protection.
- Conversion history: Converted buildings may lack fire separation present in purpose-built properties.
- Occupancy type: Bedsits have higher requirements than shared houses.
Property Categories
LACoRS categorises HMOs based on their height and type. Each category has indicative requirements for fire detection, protection, and means of escape - these are illustrative of the 2008 guidance and must be checked against the current fire risk assessment and applicable current legislation and standards.
| Category | Description | Indicative Requirements |
|---|---|---|
| 2-storey shared house | Small shared house with 3-6 occupants | Grade D LD3 alarm, fire doors on kitchen and bedrooms, 30-min escape route |
| 2-storey bedsits | Property converted to individual bedsit units | Grade A LD2 alarm, fire doors throughout, enhanced escape provisions |
| 3-storey shared house | Larger shared house across 3 floors | Grade A LD2 alarm, fire doors, emergency lighting, protected route |
| 3-storey bedsits | Multi-storey bedsit accommodation | Full LD2 system, 30-min protected route, emergency lighting, comprehensive fire doors |
| 4+ storey | High-rise HMO accommodation | Enhanced requirements, possible alternative escape, 60-min protection to escape route |
Key Requirements Summary
The following sections summarise the main provisions typically recommended by LACoRS guidance for HMOs.
Fire Detection and Alarm
- Interlinked alarms: All smoke alarms are typically interconnected so when one activates, all sound.
- Mains-powered: A Grade A system has a fire alarm control panel with its own power supply, like the systems in commercial buildings. Linked mains alarms with back-up batteries are a different grade (Grade D), not Grade A.
- Heat detectors in kitchens: Heat rather than smoke detectors to prevent false alarms from cooking.
- Escape route coverage: All escape routes typically have smoke detection as a minimum (LD3).
Fire Separation and Doors
- FD30 fire doors: LACoRS guidance indicates 30-minute fire doors on bedrooms and kitchens opening onto escape routes; confirm the required performance against the current FRA.
- Self-closing devices: Where a fire door is required, it typically needs a working self-closer.
- Protected escape route: Hallways and stairs enclosed by fire-resisting construction.
- Ceiling and wall integrity: No holes or gaps in ceilings/walls that could allow fire spread.
Meeting a recommendation is not automatically compliance
Meeting an individual recommendation does not by itself establish compliance with the Fire Safety Order. Measures must be appropriate to the premises, persons at risk and findings of the suitable and sufficient fire risk assessment.
Frequently Asked Questions
+Is LACoRS guidance legally binding?
LACoRS guidance is not itself current primary legislation, and following it does not automatically establish legal compliance. It is a widely used sector reference that should be read alongside the Fire Safety Order, the Fire Safety Act 2021, the Fire Safety (England) Regulations 2022, Section 156 of the Building Safety Act 2022 and current British Standards. Where a later legal requirement differs, follow the current requirement.+Do I have to follow LACoRS exactly?
Not necessarily. The guidance allows for equivalent measures where they achieve the same level of safety. However, any alternative approach should be documented in your fire risk assessment with justification.+What about older buildings that can't meet modern standards?
LACoRS recognises that some older buildings may have constraints. Compensatory features (such as enhanced detection or sprinklers) may be acceptable. Discuss specific situations with your local authority.
Next Steps
Need a fire risk assessment for your HMO? Book an in-person assessment with one of our assessors.
Sources
- LACoRS Housing - Fire Safety Guidance — Local Authorities Coordinators of Regulatory Services, accessed 2026-09-16
- Housing Act 2004 — UK Government, accessed 2026-09-16
- Regulatory Reform (Fire Safety) Order 2005 — UK Government, accessed 2026-09-16
- Fire Safety (England) Regulations 2022 — UK Government, accessed 2026-09-16
Need a fire risk assessment?
Tell us about the property to book an assessment by one of our assessors.