Smoke & Heat Alarm Regulations for Landlords
Guide to the Smoke and Carbon Monoxide Alarm (Amendment) Regulations 2022 for landlords. Understand your legal obligations for alarm provision.
Written for England. Check the position if your property is elsewhere in the UK.
7 min
Key takeaways
- Since 2022, the Regulations extend beyond private-rented-only properties, subject to detailed statutory scope and exclusions - check applicability to your tenancy
- At least one smoke alarm must be installed on every storey with living accommodation, where the Regulations apply
- Carbon monoxide alarms are required in rooms with fixed combustion appliances (except gas cookers), where the Regulations apply
- Alarms must be tested and working at the start of each new tenancy
- The landlord must repair or replace a required alarm as soon as reasonably practicable after being informed it is not working
- Not complying with a remedial notice can lead to a penalty charge of up to £5,000
The 2022 Regulations
The Smoke and Carbon Monoxide Alarm (Amendment) Regulations 2022 extended the England requirements beyond the former private-rented-only position, subject to the detailed tenancy scope and exclusions. Check the statutory applicability to the tenancy before relying on this page.
Where the Regulations apply, the landlord must ensure the required smoke and carbon-monoxide alarms are installed in the locations prescribed by the legislation, ensure required alarms are working on the first day of a new tenancy, and repair or replace a required alarm as soon as reasonably practicable after being informed that it is not working.
Legal Requirements
- Smoke alarm on every storey: At least one smoke alarm on every storey where there is a room used wholly or partly as living accommodation.
- Carbon monoxide alarm: In any room with a fixed combustion appliance (excluding gas cookers).
- Test at tenancy start: Ensure alarms are in proper working order at the start of each new tenancy.
- Repair after notification: Repair or replace a required alarm as soon as reasonably practicable after being informed that it is not working.
What Are Fixed Combustion Appliances?
- Gas boilers: Including combination boilers in kitchens, utility rooms, or airing cupboards.
- Gas fires and heaters: Fixed gas heating appliances in any room.
- Wood burners and open fires: Any solid fuel burning appliances.
- Oil-fired heating: Oil boilers and heaters.
Gas Cookers Exception
Gas cookers are specifically excluded from the CO alarm requirement. However, installing a CO alarm in kitchens with gas cookers is still considered good practice.
Recommended Alarm Types
| Location | Recommended Alarm | Notes |
|---|---|---|
| Hallways/Landings | Optical smoke alarm | Less prone to false alarms than ionisation |
| Living rooms | Optical smoke alarm | Positioned on ceiling away from cooking areas |
| Bedrooms | Optical smoke alarm | Centre of ceiling |
| Kitchen | Heat alarm | Use heat detector to avoid cooking false alarms |
| Room with boiler | CO alarm | At head height, 1-3m from appliance |
Testing at Tenancy Start
You must ensure all smoke and CO alarms are in proper working order on the day a new tenancy begins. This should be documented, ideally with the tenant signing confirmation that alarms were tested and working.
During the Tenancy
Once the tenancy has started, the tenant is responsible for testing alarms regularly and reporting any faults. When notified of a fault, the landlord must repair or replace the alarm as soon as reasonably practicable.
Enforcement and Penalties
Local authorities are responsible for enforcing these regulations. If you fail to comply, the local authority may issue a remedial notice requiring you to take action within 28 days. Failure to comply with a remedial notice can lead to a penalty charge of up to £5,000.
Frequently Asked Questions
+Can I use battery-only alarms?
Yes, battery-only alarms meet the minimum legal requirements. However, mains-powered alarms with battery backup are recommended as more reliable. Sealed 10-year battery alarms are not a like-for-like substitute for a recommended mains-powered system; if wiring is difficult, get competent advice before choosing them.+Do alarms need to be interlinked?
The Smoke and Carbon Monoxide Alarm Regulations do not themselves require interlinked alarms in every property. Higher provision - including interlinked systems in many HMOs - typically arises from the property's HMO/fire-safety context, licensing conditions, the fire risk assessment and applicable standards such as BS 5839-6, not from these Regulations alone.+What if a tenant removes or damages an alarm?
You should include a clause in the tenancy agreement requiring tenants not to interfere with alarms. If an alarm is damaged or removed, replace it promptly and consider whether this constitutes a breach of tenancy.
Next Steps
Document your alarm provision as part of your property fire risk assessment.
Sources
- Smoke and Carbon Monoxide Alarm (Amendment) Regulations 2022 — UK Government, accessed 2026-09-16
- Smoke and Carbon Monoxide Alarm (Amendment) Regulations 2022: guidance for landlords and tenants — Ministry of Housing, Communities & Local Government, accessed 2026-11-07
Need a fire risk assessment?
Answer a few free questions to see whether you can use our DIY assessment.