Fire Safety (England) Regulations 2022 Explained

Guide to the Fire Safety (England) Regulations 2022 and the new duties for responsible persons of multi-occupied residential buildings.

Written for England. Check the position if your property is elsewhere in the UK.

10 min

Key takeaways

  • The Fire Safety (England) Regulations 2022 came into force on 23 January 2023
  • They introduce new duties for responsible persons of multi-occupied residential buildings
  • Requirements vary by a three-tier matrix: all relevant buildings, buildings more than 11 metres high, and high-rise residential buildings (at least 18 metres or at least seven storeys)
  • The more-than-11-metres tier chiefly introduces statutory fire-door checking requirements - wayfinding signage and firefighters' lift/equipment checks are not general "over 11 metres" duties
  • Secure information boxes, external-wall information, floor/building plans, wayfinding and firefighters' lift/equipment checks apply to high-rise residential buildings (at least 18 metres or at least seven storeys)
  • A separate regime - the Fire Safety (Residential Evacuation Plans) (England) Regulations 2025, in force since 6 April 2026 - adds evacuation-planning duties for specified residential buildings, including some buildings more than 11 metres high

What are the Fire Safety Regulations 2022?

The Fire Safety (England) Regulations 2022 were made under the Fire Safety Order 2005 framework (using powers introduced by the Fire Safety Act 2021) and came into force on 23 January 2023. They set out new specific duties for responsible persons of multi-occupied residential buildings in England, building on the general duties in the Fire Safety Order.

Who Do They Apply To?

The regulations apply to responsible persons for multi-occupied residential buildings - buildings containing two or more sets of domestic premises (flats). Requirements are additive across three tiers depending on building height and status: all relevant buildings, buildings more than 11 metres high, and high-rise residential buildings. Use the statutory tests and measurement rules to classify a building - do not infer legal status from an approximate storey count.

Building Height Categories

The more-than-11-metres tier chiefly introduces statutory fire-door checking. Wayfinding, firefighters' lift/equipment checks, the secure information box, external-wall information and plans attach to high-rise residential buildings, not to the more-than-11-metres tier generally.
CategoryStatutory testDuties that apply
All relevant multi-occupied residential buildingsBuilding contains two or more sets of domestic premises within the Regulations' scopeFire-safety instructions to residents and information about the importance of fire doors
More than 11 metres highMore than 11 metres, using the statutory measurement rulesIn addition to the all-building duties: best endeavours to check every flat entrance door at least every 12 months, and check communal fire doors at least every 3 months
High-rise residential buildingAt least 18 metres high OR at least 7 storeys, using the statutory definitionsIn addition to the duties above: secure information box, external-wall information, electronic and hard-copy plans, monthly checks of firefighters' lifts and essential firefighting equipment (with reporting of qualifying faults), and wayfinding signage

Duties for All Relevant Buildings

  • Fire safety instructions: Provide fire safety instructions to residents in an accessible form.
  • Fire door information: Provide residents with information about the importance of fire doors.
  • Responsible-person information: Section 156 of the Building Safety Act 2022 introduced requirements to record responsible-person information and to share specified information with relevant persons/dutyholders. This is not the same as a general legal requirement to display the responsible person's name and contact details somewhere visible. Check whether another rule that applies to your premises specifically requires them to be displayed.

What the More-Than-11-Metres Tier Adds

  • Quarterly communal fire door checks: Check fire doors in communal areas at least every 3 months.
  • Annual flat entrance door checks (best endeavours): Use best endeavours to check every flat entrance fire door at least every 12 months.

High-Rise Residential Buildings: At Least 18 Metres or At Least 7 Storeys

  • External wall information: Provide the fire and rescue service with information about materials in external walls.
  • Floor and building plans: Maintain up-to-date electronic and hard-copy plans and provide them to the fire and rescue service.
  • Secure information box: Install a box for the fire and rescue service containing key building information.
  • Firefighters' lift and equipment checks: Carry out monthly checks of lifts intended for use by firefighters and essential firefighting equipment, and report qualifying faults to the fire and rescue service.
  • Wayfinding signage: Install floor identification / wayfinding signage - this is a high-rise duty, not a general more-than-11-metres duty.

The 2025 Residential Evacuation Plans Regulations are a separate regime

From 6 April 2026, the Fire Safety (Residential Evacuation Plans) (England) Regulations 2025 impose additional duties for specified residential buildings, including identifying relevant residents, person-centred fire risk assessments and emergency evacuation statements. These duties are additional to the 2022 Regulations and are not part of them, and a building's evacuation-plan duties don't follow from its height alone. See the IgniRisk Residential Evacuation Plans guide.

Fire Door Check Requirements

Regulation 10's statutory frequencies apply to qualifying buildings more than 11 metres high: communal fire doors checked at least every 3 months, and flat entrance doors checked using best endeavours at least every 12 months. Separately from that statutory frequency, what counts as an acceptable door on inspection - self-closing function, condition, seals, hinges and certification evidence - depends on the door's required performance and location; these technical indicators are not a universal legal specification for every historical door in every building. See the dedicated fire-door guidance for inspection detail.

Enforcement

The regulations are enforced by fire and rescue authorities using the existing enforcement regime under the Fire Safety Order. This includes the power to issue enforcement notices, prohibition notices, and prosecute.

Frequently Asked Questions

  • +When did these regulations come into force?
    The Fire Safety (England) Regulations 2022 came into force on 23 January 2023. All responsible persons should now be compliant with these requirements.
  • +Do these regulations apply in Wales?
    No. The Fire Safety (England) Regulations 2022 apply only in England. Wales has separate arrangements under Welsh Government.
  • +Do I need to retrofit buildings to comply?
    The regulations don't require physical changes to buildings beyond what's needed to comply with the Fire Safety Order. However, you may need to install signage, information boxes, and ensure fire doors are adequate.
  • +Do these regulations require PEEPs?
    No. The Fire Safety (England) Regulations 2022 do not contain a PEEP requirement. Since 6 April 2026, the separate Fire Safety (Residential Evacuation Plans) (England) Regulations 2025 impose a structured evacuation-planning regime, including reasonable endeavours to identify relevant residents, for specified residential buildings.

Next Steps

Ensure you have implemented all requirements for your building's height category.

Ask us about your building

Sources